Hornet and Bee Installation Guide Installation
MAN-HRBEIG (Ver. 1.3)
www.elmomc.com
48
Figure 30: RS-232 Connection Diagram
3.12.2. CANopen Communication
Notes for connecting the CANopen communication cable:
• Connect the shield to the ground of the host (PC). Usually, this connection is soldered
internally inside the connector at the PC end. You can use the drain wire to facilitate
connection.
• Ensure that the shield of the cable is connected to the shield of the connector used for
communications. The drain wire can be used to facilitate the connection.
• Make sure to have a 120-Ω resistor termination at each of the two ends of the network
cable.
• The Hornet and Bee’s CAN ports are non-isolated.
Pin (J1) Signal Function Pin Positions
20 CAN_GND CAN ground
21 CAN_L CAN_L busline (dominant low)
22 CAN_H CAN_H busline (dominant high)
Table 12: CANopen - Pin Assignments